Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int Endod J ; 57(5): 601-616, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38376108

RESUMO

AIM: To compare eight large- and low-tapered heat-treated reciprocating instruments regarding their design, metallurgy, mechanical properties, and irrigation flow through an in silico model. METHODOLOGY: A total of 472 new 25-mm E-Flex Rex (25/.04 and 25/.06), Excalibur (25/.05), Procodile (25/.06), Reciproc Blue R25 (25/.08v), WaveOne Gold Primary (25/.07v), and Univy Sense (25/.04 and 25/.06) instruments were evaluated regarding their design (stereomicroscopy, scanning electron microscopy, and 3D surface scanning), metallurgy (energy-dispersive X-ray spectroscopy and differential scanning calorimetry), and mechanical performance (cyclic fatigue, torsional resistance, cutting ability, bending and buckling resistance). Computational fluid dynamics assessment was also conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparations. Kruskal-Wallis and one-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Instruments presented variations in blade numbers, helical angles, and tip designs, with all featuring non-active tips, symmetrical blades, and equiatomic nickel-titanium ratios. Cross-sectional designs exhibited an S-shaped geometry, except for WaveOne Gold. Univy 25/.04 and Reciproc Blue displayed the smallest and largest core diameters at D3. Univy 25/.04 and E-Flex Rec 25/.04 demonstrated the longest time to fracture (p < .05). Reciproc Blue and Univy 25/.04 exhibited the highest and lowest torque to fracture, respectively (p < .05). Univy 25/.04 and Reciproc Blue had the highest rotation angles, whilst E-Flex Rec 25/.06 showed the lowest angle (p < .05). The better cutting ability was observed with E-Flex Rec 25/.06, Procodile, Excalibur, and Reciproc Blue (p > .05). Reciproc R25 and E-Flex Rec showed the highest buckling resistance values (p < .05), with WaveOne Gold being the least flexible instrument. The impact of instruments' size and taper on wall shear stress and apical pressure did not follow a distinct pattern, although Univy 25/.04 and E-Flex Rec 25/.06 yielded the highest and lowest values for both parameters, respectively. CONCLUSIONS: Low-tapered reciprocating instruments exhibit increased flexibility, higher time to fracture, and greater angles of rotation, coupled with reduced maximum bending loads and buckling strength compared to large-tapered instruments. Nevertheless, low-tapered systems also exhibit lower maximum torque to fracture and inferior cutting ability, contributing to a narrower apical canal enlargement that may compromise the penetration of irrigants in that region.


Assuntos
Instrumentos Odontológicos , Titânio , Estudos Transversais , Desenho de Equipamento , Teste de Materiais , Estresse Mecânico , Titânio/química , Preparo de Canal Radicular , Metalurgia
2.
Int Endod J ; 56(11): 1412-1428, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37698946

RESUMO

AIM: To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model. METHODOLOGY: New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS: Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm3 ) and surface area (32.32 mm2 ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments. CONCLUSIONS: Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.


Assuntos
Instrumentos Odontológicos , Temperatura Alta , Desenho de Equipamento , Estresse Mecânico , Preparo de Canal Radicular , Titânio/química , Metalurgia , Ouro , Teste de Materiais
3.
Int Endod J ; 56(10): 1301-1315, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37594701

RESUMO

AIM: To assess the influence of a flat-side design on the geometry, metallurgy, mechanical performance and shaping ability of a novel nickel-titanium rotary instrument. METHODOLOGY: Sixty-five new 25-mm flat-side rotary instruments (size 25, taper 0.04) and their nonflat-side prototypes (n = 65) were assessed for major deformations and examined regarding macroscopic and microscopic design, determination of nickel and titanium elements ratio, measurement of phase transformation temperature and evaluation of mechanical performance parameters including time/cycles to fracture, maximum torque, angle of rotation, maximum bending and buckling strengths and cutting ability. Additionally, unprepared canal areas, volume of hard tissue debris and percentage reduction of dentine thickness were calculated for each tested instrument after preparing mesial canals of mandibular molars (n = 12), using micro-CT imaging. Statistical analyses were performed using the U-Mann-Whitney test and independent Student t-test (α = 5%). RESULTS: The number of spirals (n = 8) and blade direction (clockwise) were similar between both flat and nonflat instruments, whilst the helical angles were equivalent (⁓25°). Flat-instruments showed inconsistencies in the homogeneity of the gold colour on the flat-side surface, blade discontinuity, and incomplete and variable S-shaped cross-sections. The titanium-to-nickel ratios were equivalent, but significant differences in the R-phase finish and austenitic start phase transformation temperatures were observed between the flat and nonflat-side instruments. The flat-side instruments demonstrated superior cutting ability compared to the nonflat instruments, as well as, significantly lower values for time to fracture, rotation to fracture and maximum torque to fracture (p < .001). No statistical difference was observed between tested instruments regarding angle of rotation (p = .437), maximum bending (p = .152) and buckling load (p = .411). Preparation protocols using flat and nonflat instruments did not show any statistically significant differences (p > .05). All flat-side instruments exhibited deformation after shaping procedures. CONCLUSIONS: The flat-side instrument showcased enhanced cutting ability compared to its nonflat counterpart. However, it exhibited inferior performance in terms of time, rotation and maximum torque to fracture, along with distinct phase transformation temperatures. No differences were observed in the titanium-to-nickel ratios, angle of rotation, maximum bending, buckling load, preparation time, percentage of untouched canal walls, volume of hard tissue debris and percentage reduction of dentine thickness.


Assuntos
Níquel , Titânio , Humanos , Cavidade Pulpar , Metalurgia , Dente Molar
4.
Int Endod J ; 56(6): 775-785, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36942476

RESUMO

AIM: This study aimed to compare three rotary instruments produced by the EDM process with the heat-treated ProTaper Gold system regarding design, metallurgy, mechanical properties and shaping ability. METHODOLOGY: HyFlex EDM (25/~), Neoniti (25/.06), EDMax (25/.06) and ProTaper Gold (25/.08v) instruments (n = 58 per group) were compared regarding design, metallurgy and mechanical performance. Unprepared canal areas were calculated for each system after preparation of mesiobuccal, mesiolingual and distal canals of mandibular molars (15 canals per group) using micro-CT technology. Statistical analyses were performed using One-way anova post-hoc Tukey and Kruskal-Wallis post-hoc Dunn's tests (α = 5%). RESULTS: All instruments had asymmetrical blades, no radial lands, no major defects and almost equiatomic nickel/titanium ratios, but different cross-section designs, tip geometries and surface appearances. Although instruments had distinct transformation temperature curves, they showed crystallographic martensitic arrangement at 21°C and mixed austenite plus R-phase at body temperature. Neoniti and HyFlex EDM showed similar results in all mechanical tests (p > .05), while EDMax and ProTaper Gold had similar time to fracture (p = .841), maximum bending load (p = .729), and cutting ability (p = .985). ProTaper Gold showed the highest torque to failure (p < .001) and HyFlex EDM had the lowest buckling resistance (p < .001). Mean percentages of unprepared canal areas ranged from 20.4% to 25.7% in the mesial canals, and from 20.8% to 26.2% in the distal canal, with no statistical differences among systems (p > .05). CONCLUSIONS: Instruments' geometry and phase transformation temperatures influenced the results of the mechanical tests, but not their shaping ability.


Assuntos
Preparo de Canal Radicular , Humanos , Ligas Dentárias/química , Instrumentos Odontológicos , Desenho de Equipamento , Teste de Materiais , Temperatura , Titânio/química , Torque
5.
Clin Oral Investig ; 27(5): 2427-2436, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36749411

RESUMO

OBJECTIVE: This study aimed to compare 3 reciprocating systems regarding design, metallurgy, mechanical properties, and shaping ability. MATERIALS AND METHODS: New Reciproc Blue R25, WaveOne Gold Primary, and REX 25 instruments (n=41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin, and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. Results were compared using one-way ANOVA post hoc Tukey and Kruskal-Wallis tests with a significant level set at 5%. RESULTS: All instruments showed symmetrical cross sections with asymmetrical blades, no radial lands, no major defects, and an almost equiatomic nickel and titanium ratio. The highest R-phase start temperatures were observed with WaveOne Gold (46.1°C) and REX (44.8°C), while Reciproc Blue had the lowest R-phase start (34.5°C) and finish (20°C) temperatures. WaveOne Gold had the lowest time to fracture (169 s) and the highest maximum load (301.6 gf) (P <0.05). The maximum torque of Reciproc Blue (2.2 N.cm) and WaveOne Gold (2.1 N.cm) were similar (P >0.05), but lower than REX (2.6 N.cm) (P <0.05). No statistical differences were observed among instruments in the angle of rotation (P >0.05) and in the shaping ability in both mesial and distal canals (P >0.05). CONCLUSION: Although the overall design, temperature transition phases and mechanical behavior parameters were different among tested instruments, they were similar in terms of shaping ability. CLINICAL RELEVANCE: All tested heat-treated NiTi reciprocating systems showed similar shaping ability, without clinically significant errors.


Assuntos
Temperatura Alta , Preparo de Canal Radicular , Instrumentos Odontológicos , Desenho de Equipamento , Titânio , Metalurgia , Teste de Materiais
6.
J Endod ; 49(3): 301-306, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36567061

RESUMO

INTRODUCTION: The aim of this study was to compare E1-Irrisonic (Helse Ultrasonics, Ocoee, FL) and Irri Black (Helse Ultrasonics), a novel ultrasonic tip with diamondlike carbon treatment, regarding their design, metallurgy, microhardness, bending resistance, and time to fracture under the oscillatory fatigue test. METHODS: A total of 17 E1-Irrisonic and 17 Irri Black new ultrasonic tips were selected. The tip geometry and surface finishing were assessed using scanning electron microscopy. The elemental composition was defined by energy-dispersive X-ray spectroscopy. Hardness Knoop was calculated using a microhardness tester. The maximum load required to displace the instrument in 45° was recorded in gram/force, oscillatory fatigue was measured in seconds at the moment of instrument fracture, and the size of the separate fragments was determined in millimeters. The Student t test was used for statistical comparison (α = 5%). RESULTS: Scanning electron microscopic analyses revealed that E1-Irrisonic had a flat end tip, whereas a noncutting rounded tip was observed in Irri Black. The surface of E1-Irrisonic was smoother than Irri Black, which was irregular. Energy-dispersive X-ray spectroscopic analyses showed that the elemental compositions of the E1-Irrisonic and Irri Black tips were consistent with stainless steel and titanium-aluminum alloys, respectively. Irri Black showed significantly higher bending load resistance, time to fracture under oscillatory motion, and hardness Knoop than the E1-Irrisonic tip (P < .05), whereas the length of fragments was similar (P > .05). CONCLUSION: Diamondlike carbon treatment improved hardness Knoop and reduced the flexibility of the Irri Black ultrasonic tip, improving its time to fracture under oscillatory motion compared with the nontreated E1-Irrisonic tip.


Assuntos
Carbono , Ultrassom , Humanos , Dureza , Titânio/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Desenho de Equipamento , Preparo de Canal Radicular
7.
Int Endod J ; 56(4): 530-542, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36508297

RESUMO

AIM: To compare design, metallurgy and mechanical performance of the ProTaper (PT) Ultimate system with instruments of similar dimensions from the ProGlider, PT Gold and PT Universal systems. METHODOLOGY: New PT Ultimate instruments (n = 248) were compared with instruments of similar dimensions from ProGlider (n = 31), PT Gold (n = 155) and PT Universal (n = 155) systems regarding their number of spirals, helical angle, blade symmetry, tip geometry, surface finishing, nickel/titanium ratio, phase transformation temperatures and mechanical performance. One-way anova and nonparametric Mood's median tests were used for statistical comparison (α = 5%). RESULTS: All instruments had symmetrical blades without radial lands or flat sides, similar surface finishing and an almost equiatomic nickel/titanium ratio, whilst the number of spirals, helical angles and the tip geometry were different. PT Ultimate instruments showed 3 distinct heat treatments that matched with the colour of their metal wire. Slider and ProGlider instruments had similar R-phase start (Rs) and R-phase finish (Rf) temperatures. SX, F1, F2, F3 and Shaper instruments showed equivalent heat treatments (Rs ~45.6°C and Rf ~28.3°C) that were similar to their PT Gold counterparts (Rs ~47.9°C and Rf ~28.2°C), but completely distinct to the PT Universal ones (Rs ~16.2°C and Rf ~-18.2°C). Amongst the PT Ultimate instruments, the lowest maximum torques were observed in the SX (0.44 N cm), Slider (0.45 N cm) and Shaper (0.60 N cm) instruments, whilst the highest was noted in the FXL (4.90 N cm). PT Ultimate Slider and ProGlider had similar torsional (~0.40 N cm) and bending loads (~145.0 gf) (p = 1.000), whilst the other PT Ultimate instruments showed statistically significantly lower maximum torque, higher angle of rotation and lower bending load (higher flexibility) than their counterparts of the PT Universal and PT Gold systems. CONCLUSIONS: The PT Ultimate system comprises instruments with 3 distinct heat treatments that showed similar phase transformation temperatures to their heat-treated analogues. PT Ultimate instruments presented lower torsional strength and superior flexibility than their counterparts, whilst maximum torque, angle of rotation and bending loads progressively increased with their sizes.


Assuntos
Níquel , Titânio , Temperatura Alta , Falha de Equipamento , Teste de Materiais , Ligas Dentárias , Preparo de Canal Radicular , Desenho de Equipamento , Torção Mecânica
8.
J Endod ; 48(8): 985-1004, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35667567

RESUMO

Instruments' mechanical strength and flexibility are traditionally tested by running cyclic fatigue, torsional, bending, buckling, and microhardness tests. Several cyclic fatigue test models have been used in endodontics, all capable of providing a curved trajectory for the instrument to rotate. Cyclic fatigue testing allows the identification of conditions that may affect the fatigue strength outcomes, such as the canal radius and degree of curvature, handpiece static versus dynamic motions, test temperature, kinematics, instrument previously wear and sterilization cycles, or instrument's size and metal alloy features. Because of the international test specifications for both torsional and bending tests, the variations of their models are not as many as for cyclic fatigue. These tests have also identified conditions capable of affecting the outcomes, such as kinematics, instruments' preloading, cross-sectional diameters, or alloy heat treatments. Buckling and microhardness are less common, with the metal alloy being considered to have a major influence on the results. Instruments' mechanical testing, having all these individual conditions as independent variables, allowed the understanding of them and molded the way the technical procedures are performed clinically. Even though the artificiality and simplicity of these tests will hardly mimic real working situations, and independent of being capable of producing cornerstone knowledge, these tests are also associated with inconsistency, a lack of reproducibility, and low external validity. Several attempts have been made to increase the generalizability of the outcomes by adding test settings that intend to mimic the clinical condition. Although pertinent, these settings may also add variabilities inherent to their concepts and practical applications in the laboratory environment. Although the actual studies should be seen as laboratory mechanical tests that measure very specific parameters under very particular conditions and that by far do not mimic the clinical condition, the lower validity drawback seems to be possible to be minimized when achieving a comprehensive understanding of the instrument behavior. A finite element method and/or a multimethod research approach may lead to superior data collection, analysis, and interpretation of results, which when associated with a reliable confounding factor control and proper study designs may be helpful tools and strategies in order to increase the reliability of the outcomes.


Assuntos
Níquel , Titânio , Ligas , Ligas Dentárias , Instrumentos Odontológicos , Desenho de Equipamento , Teste de Materiais , Testes Mecânicos , Reprodutibilidade dos Testes , Preparo de Canal Radicular , Estresse Mecânico , Torção Mecânica
9.
Dent J (Basel) ; 10(2)2022 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-35200255

RESUMO

BACKGROUND: The aim of this study was to comprehensively evaluate the cyclic fatigue strength of ProGlider, Edge Glide Path, and R-Pilot instruments. METHODS: Sixty-three instruments were submitted to a multimethod evaluation. Their design was analyzed by stereomicroscopy and scanning electron microscopy, including the number of blades, helical angle means, cross-sectional design, surface finishing, and symmetry. Energy-dispersive X-ray spectroscopy was used determine the nickel/titanium elements ratio, and differential scanning calorimetry determined the instruments' phase transformation temperatures. The cyclic fatigue tests were conducted in an artificial canal with a 6 mm radius and 86 degrees of curvature. The Mood's median test and one-way ANOVA were used to determine differences, with the significance level set at 0.05. RESULTS: The ProGlider presented the highest number of blades (n = 21), while R-Pilot had the highest helical angles (26.4°). Differences were noted in the instruments' cross-sections and surface finishing. The ProGlider and R-Pilot showed some similarities regarding the phase transformation temperatures but differed from the Edge Glide Path. All alloys showed an almost equiatomic nickel/titanium ratio. The R-Pilot instruments showed a significantly higher (p < 0.05) time to fracture than both the other files. CONCLUSION: Reciprocating R-Pilot instruments showed a higher cyclic fatigue time to fracture than the ProGlider and Edge Glide Path rotary files.

10.
Clin Oral Investig ; 26(3): 3299-3310, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34860307

RESUMO

OBJECTIVES: To compare the design, metallurgy, mechanical performance, and canal preparation of 5 rotary systems. MATERIAL AND METHODS: A total of 735 25-mm NiTi instruments (sizes 0.17[0.18]/.02v, 0.20/.04v, 0.20/.07v, 0.25/.08v, 0.30/.09v) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-File systems were compared regarding overall geometry and surface finishing (stereomicroscopy and scanning electron microscopy), nickel and titanium ratio (energy-dispersive spectroscopy), phase transformation temperatures (differential scanning calorimetry), mechanical performance (torsional and bending tests), and unprepared canal surface (micro-CT). One-way ANOVA and Mood's median tests were used for statistical comparisons with a significance level set at 5%. RESULTS: Stereomicroscopic analysis showed more spirals and high helical angles in the Premium Taper Gold system. All sets of instruments had symmetrical spirals, no radial lands, no major defects, and an almost equiatomic ratio between nickel and titanium elements, while differences were observed in their tips' geometry and surface finishing. At room temperature (20 °C), DSC test revealed martensitic characteristics for ProTaper Gold and Go-Taper Flex, and mixed austenite plus R-phase for the Premium Taper Gold, while ProTaper Universal and U-Files had full austenitic characteristics. Overall, larger instruments had higher torque resistance and bending load values than smaller ones, while a lack of consistency and mixed values were observed in the angle of rotation. The 0.25/.08v and 0.30/.09v instruments of ProTaper Universal and U-File had the highest maximum torques, the lowest angles of rotation, and the highest bending loads than other tested systems (P < .05). No significant difference was noted regarding the untouched root canal walls after preparation with the tested systems (P > .05). CONCLUSIONS: Although differences observed in the overall geometry and phase transformation temperatures have influenced the results of mechanical tests, unprepared canal surface areas were equivalent among systems. CLINICAL RELEVANCE: Root canal preparation systems with similar geometries might present different mechanical behaviors but equivalent shaping ability.


Assuntos
Ligas Dentárias , Preparo de Canal Radicular , Ligas Dentárias/química , Desenho de Equipamento , Teste de Materiais , Metalurgia , Estresse Mecânico , Titânio/química
11.
J Endod ; 47(12): 1917-1923, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34537227

RESUMO

INTRODUCTION: This study aims to compare the design, metallurgy, microhardness, and mechanical properties of 3 glide path nickel-titanium (NiTi) instruments. METHODS: A total of 132 ProGlider (Dentsply Sirona, Ballaigues, Switzerland), Edge Glide Path (EdgeEndo, Johnson City, TN), and R-Pilot instruments (VDW, Munich, Germany) (44 per group) were selected. Design was assessed through stereomicroscopy (blades, helical angle, measuring lines, and deformation) and scanning electron microscopy (symmetry, cross section, tip, and surface finishing). NiTi ratios were measured by energy-dispersive X-ray spectroscopy and phase transformation temperatures by differential scanning calorimetry. Microhardness and mechanical performance (torsion, bending, and buckling resistance tests) were also evaluated. Statistical analyses were performed with the Mood median test with a significance set at 5%. RESULTS: The Edge Glide Path had the lowest number of blades and the R-Pilot the greatest helical angle. All instruments had an almost equiatomic NiTi ratio, while showing different cross sections and tip geometries. The Edge Glide Path had a smoother surface finishing. The R-Pilot showed martensitic characteristics at room temperature, whereas mixed austenite plus R-phase was observed in the other instruments. The R-Pilot had higher results on the microhardness (436.8 hardness Vickers number), maximum torsion (0.9 Ncm), and buckling load (0.7 N) tests (P < .05), whereas the Edge Glide Path had a superior angle of rotation (683.5°) and the ProGlider was more flexible (144.1 gf) (P < .05). CONCLUSIONS: Differences in the design of the instruments and the phase transformation temperatures accounted for their mechanical behavior. The R-Pilot showed the highest torque, buckling, and microhardness, whereas the ProGlider instrument was the most flexible.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular , Desenho de Equipamento , Teste de Materiais , Metalurgia , Estresse Mecânico , Titânio , Torção Mecânica
12.
Materials (Basel) ; 14(16)2021 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-34442977

RESUMO

The interaction between the stress-induced martensitic transformation and resistivity behavior of superelastic NiTi shape memory alloy (SMA) was studied. Strain-controlled low-cycle fatigue up to 6% was monitored by in situ electrical resistivity measurements. The experimental results show that a great motion of martensite fronts results in a significant accumulation of defects, as evidenced by transmission electron microscopy (TEM), before and after the tensile cycles. This gives rise to an overall increase of the resistivity values up to the maximum deformation. Therefore, the research suggests that shape memory alloy wire has great potential as a stress sensor inside bulk materials.

13.
Materials (Basel) ; 15(1)2021 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-35009213

RESUMO

The structural and thermophysical characteristics of an Ni-rich NiTi alloy rod produced on a laboratory scale was studied. The soak temperature of the solution heat-treatment steps above 850 °C taking advantage of the precipitate dissolution to provide a matrix homogenization, but it takes many hours (24 to 48) when used without thermomechanical steps. Therefore, the suitable reheating to apply between the forging process steps is very important, because the product's structural characteristics are dependent on the thermomechanical processing history, and the time required to expose the material to high temperatures during the processing is reduced. The structural characteristics were investigated after solution heat treatment at 900 °C and 950 °C for 120 min, and these heat treatments were compared with as-forged sample structural characteristics (one hot deformation step after 800 °C for a 30 min reheat stage). The phase-transformation temperatures were analyzed through differential scanning calorimetry (DSC), and the structural characterization was performed through synchrotron radiation-based X-ray diffraction (SR-XRD) at room temperature. It was observed that the solution heat treatment at 950 °C/120 min presents a lower martensitic reversion finish temperature (Af); the matrix was fully austenitic; and it had a hardness of about 226 HV. Thus, this condition is the most suitable for the reheating stages between the hot forging-process steps to be applied to this alloy to produce materials that can display a superelasticity effect, for applications such as crack sensors or orthodontic archwires.

14.
J Endod ; 46(12): 1884-1893, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32898557

RESUMO

INTRODUCTION: This study aimed to compare the ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland) system with 6 replicalike instruments regarding instrument design, mechanical performance, and alloy characteristics. METHODS: New rotary instruments (size 20/.07v) of PTU and 6 replicalike systems (EdgeTaper [EdgeEndo, Johnson City, TN], U-File [Dentmark, Ludhiana, India], Go-Taper Universal [Access, Shenzhen, China], Super Files [Flydent, Shenzhen, China], Multitaper [Proclinic Expert, Besançon, France], and Pluri Taper [Bestdent, Shenzhen, China]) (n = 329) were selected and evaluated regarding their design, mechanical performance, and metallurgical characteristics. The results were compared using the nonparametric Mood median test and 1-way analysis of variance with the significance level set at 0.05. RESULTS: Replicalike instruments were similar to PTU regarding design, maximum torque to fracture (P > .05), and ratio of nickel and titanium elements. Scanning electron microscopy revealed differences in the geometry of the tip and finishing surfaces. Time to fracture of Go-Taper Universal (50.0 seconds) was similar to PTU (44.0 seconds) (P > .05), but the U-File (63.5 seconds), Edge Taper (87.5 seconds), and Super Files (130 seconds) showed significantly higher values (P < .05). The highest maximum torque was observed in the Super Files instrument (P < .05), but no statistical difference was noted among the other instruments (P > .05). The angle of rotation before rupture of the Multitaper (574°) and Pluri Taper (481°) was higher than PTU (354°) (P < .05). Differential scanning calorimetric analysis showed clear differences on the transformation temperatures among the tested instruments. The R-phase start and finish temperatures of PTU were 11.0°C and -18.0°C, respectively. CONCLUSIONS: Overall, replicalike instruments were similar to PTU regarding the torsional resistance, geometric design, and near equiatomic proportions of nickel and titanium elements. In 3 of the 4 mechanical tests, the EdgeTaper (torque, angle of rotation, and bending load) and Go-Taper Universal (time to fracture, torque, and angle of rotation) systems were similar to PTU.


Assuntos
Ligas Dentárias , Preparo de Canal Radicular , China , Desenho de Equipamento , Falha de Equipamento , França , Índia , Teste de Materiais , Estresse Mecânico , Titânio , Torção Mecânica
15.
J Endod ; 46(8): 1136-1143, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32413441

RESUMO

INTRODUCTION: The aim of this study was to evaluate the cyclic fatigue resistance of 3 replicalike rotary instruments compared with their original brand systems using continuous rotation and optimum torque reverse (OTR) kinematics. METHODS: New F1 rotary instruments (n = 20 per group) from ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland) and ProTaper Gold (Dentsply Maillefer) original brand systems were compared with 3 replicalike instruments (U-File [Dentmark, Ludhiana, India], Super Files [Shenzhen Flydent Medical, Shenzhen, China], and Super Files Blue [Shenzhen Flydent Medical]) regarding cyclic fatigue resistance. In each group, the selected instruments were randomly distributed into 2 subgroups (n = 10) according to the kinematics. In the rotary group (ROT), the instruments were activated with a continuous clockwise rotation (300 rpm, 1.5 Ncm), whereas in the OTR group, asymmetric oscillatory motion was performed setting the OTR function at 300 rpm and adjusting the torque limit at the minimum level using the TriAuto ZX2 motor (J Morita, Kyoto, Japan). The time to fracture was recorded and statistically compared according to the kinematics (ROT × OTR) and the instrument type (replicalike × original brand) using the independent sample t test (α = 0.05). Additionally, the metal alloy characterization of each system was performed by differential scanning calorimetry and energy-dispersive X-ray spectroscopy. RESULTS: Statistical analysis revealed significantly higher time to fracture for all rotary systems tested in OTR motion compared with continuous rotation (P < .05) with a mean percentage increase ranging from 52.1% (ProTaper Gold) to 156.7% (U-File). The replicalike instruments showed a significantly higher time to fracture compared with the respective original brand instruments in either ROT or OTR motion (P < .05). Replicas presented austenitic temperatures above the ones displayed by the original brands and an almost equiatomic ratio between nickel and titanium elements. CONCLUSIONS: OTR motion significantly improved the fatigue resistance of both original and replicalike systems. The replicas showed higher cyclic fatigue resistance than original brand instruments and higher transition temperatures to the austenitic phase.


Assuntos
Ligas Dentárias , Falha de Equipamento , Fenômenos Biomecânicos , China , Instrumentos Odontológicos , Desenho de Equipamento , Índia , Preparo de Canal Radicular , Rotação , Estresse Mecânico , Titânio
16.
J Synchrotron Radiat ; 21(Pt 3): 638-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24763656

RESUMO

Transnational access (TNA) to national radiation sources is presently provided via programmes of the European Commission by BIOSTRUCT-X and CALIPSO with a major benefit for scientists from European countries. Entirely based on scientific merit, TNA allows all European scientists to realise synchrotron radiation experiments for addressing the Societal Challenges promoted in HORIZON2020. In addition, by TNA all European users directly take part in the development of the research infrastructure of facilities. The mutual interconnection of users and facilities is a strong prerequisite for future development of the research infrastructure of photon science. Taking into account the present programme structure of HORIZON2020, the European Synchrotron User Organization (ESUO) sees considerable dangers for the continuation of this successful collaboration in the future.

17.
ScientificWorldJournal ; 2014: 976459, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24574937

RESUMO

The purpose of this study is to understand how the M-Wire alloy conditions the mechanical flexibility of endodontic rotary files at body temperature.Two different rotary instruments, a Profile GT 20/.06 and a Profile GT Series X 20/.06, were selected due to their geometrical similarity and their different constituent alloy. GT series X files are made from M-Wire, a Ni-Ti alloy allegedly having higher flexibility at body temperature. Both files were analysed by X-Ray Diffraction and Differential Scanning Calorimetry to investigate phase transformations and the effects of working temperature on these different alloys. Mechanical behaviour was assessed by means of static bending and torsional Finite Element simulations, taking into account the nonlinear superelastic behaviour of Ni-Ti materials. It was found that GT files present austenitic phase at body temperature, whereas GT series X present R-phase at temperatures under 40 °C with a potential for larger flexibility. For the same load conditions, simulations showed that the slight geometrical differences between the two files do not introduce great disagreement in the instruments' mechanical response. It was confirmed that M-Wire increases the instrument's flexibility, mainly due to the presence of R-phase at body temperature.


Assuntos
Ligas Dentárias/química , Elasticidade , Níquel/química , Titânio/química , Temperatura Corporal , Endodontia/instrumentação , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...